- A set of polarisation response angles. - The standard choice to consider the polarisation response of the reciever is by - instrument_pol, and this response becomes then part of- sensor_response. However, that choice is not possible when the polartisation response changes between measurement blocks, and this variable combined with the- yApplySensorPol()offers an alternative for such situations. This WSV also allows defintion of an arbitrary polarisation angle.- When applying the polarisation response by - yApplySensorPol(), this variable complements- sensor_posand- sensor_los. This WSV matrix is also a matrix, that shall have the same number of rows as the other two matrices.- The columns of - sensor_polcorresponds to the channels/frequencies of the receiver. Each element gives the polarisation angle. A pure vertical response has the angle 0 deg, and pure horisontal 90 deg. If all U values (Stokes element 3) are zero, the sign of the angle does, not matter, and 0 and 180 degrees give the same result. With non-zero U, the result of e.g. -45 and +45 degrees differ.- Note that a receiver with a linear response is assumed. Circular polarisation is not affected by any rotation. - Usage: Set by the user. - Unit: [ degrees ] - Size: [ number of measurement blocks, number of channels/frequencies ] - Workspace methods that require sensor_pol- Generic workspace methods that can generate or use sensor_pol- type: